Skip to content

connect

Positions with this command: switch (Switching Station Technician).


NAME
     connect - work another office from this console

SYNOPSIS
     connect
     connect clli
     connect home

DESCRIPTION
     A switching control centre watches a group of offices from one
     console. This is that: reach another building by its CLLI code, by the
     start of its city name, or by its number in the listing.

     With no argument, list the offices this console watches and mark the
     one you are on. connect home comes back.

     While connected, alarm(1) reads the office you are connected to, which
     has its own alarms and its own health. Acknowledging one office's
     alarm does not touch another's.

     The trouble board does NOT travel. A customer loop lands on exactly
     one frame in one building, so its report stays there. What travels is
     everything above the loop: the switching machine, its alarms and its
     records. That division is not a simplification - it is why a control
     centre could watch eleven offices and a repair service bureau could
     not.

EXAMPLES
     connect                       what is on the console
     connect NWRKNJCOCG0          by code
     connect Newark               by place
     connect home                 back to the building you can walk to

SEE ALSO
     alarm(1), switch(1), coer(1), company(1), sarts(1)

QUALIFICATION VERB
     connect pool <force>

     Held with the Switching Control Center sign-off. The control centre
     keeps one crew in a pool. This lends it to the wire centre for the
     rest of the tour as an extra crew for the category you name, for the
     times everybody who answers that category is already out. It starts
     at the far end of the district, so the first trip is a long one. One
     a tour, and it costs 12 minutes to ask for. 'force' shows where the
     crew is.

At the Switching Station Technician desk

The game adds this only for switch.


ALARM PANEL
     connect work
     connect work ALARM

     The Switching Station Technician desk only. With no argument, the
     panel: every alarm standing on every office this console watches,
     the lamp it now shows, how many shift minutes until the lamp rises
     (while the lamps run), what clearing it would cost, and a line saying
     what it reads. Naming an alarm clears it at its cause, and the shift
     loses the minutes.

     An alarm nobody works lights one lamp higher every 40 shift minutes,
     from its own point in them, so they do not all rise together. The
     lamp sets the cost: 3 minutes at MINOR, 5 at MAJOR, 8 at CRITICAL,
     and 2 more for a building you are not in. alarm ack does not stop
     the rising; only clearing does.

     Some alarms are only a symptom of another. A symptom's reads line
     names the system of the alarm that explains it, which is how to
     match the two: a trunk group failing on the trunks riding a carrier,
     a carrier dropping in step with a microwave span, parity errors when
     backup power sags. Clear the cause and everything it explains clears
     with it, for no more time. Work only a symptom and the minutes are
     spent and nothing clears: it stays on the panel until its cause is
     cleared.

     An alarm in your own building that has stood a whole span (40
     minutes) at the top lamp is a missed commitment, counted on the
     service index at the handoff whether or not you ever looked at the
     panel. The span runs from when the lamp reached the top, so one
     dealt at the top lamp is held from minute 40. One cleared before
     then is not; one cleared after it still is, and stays on the
     index. The other buildings' lamps rise and show on the panel but
     are not on the index. Each tour deals the alarms again, the same ones
     for the same tour however many times the shift is resumed. The lamps
     run only on a tour that began with the Switching Control Center
     sign-off, which is what connect work waits on: the first tour, and
     the tour the sign-off is passed in, are a grace, with nothing
     climbing and nothing counted: the panel drops its NEXT column and
     says the lamps are not running. The clock is the shift clock and not
     a stopwatch.
     These figures are the simulation's own.