regenerator
NAME
regenerator - Digital signal regenerator management
SYNOPSIS
regenerator [status|test|alignment|performance] [regen-id]
DESCRIPTION
Monitor and maintain digital signal regenerators for T1 carrier
systems. Regenerators restore digital pulse timing and amplitude
at regular intervals along transmission facilities.
OPTIONS
status Display regenerator operational status
test Execute regenerator performance tests
alignment Timing and threshold adjustments
performance Monitor regenerator performance metrics
TECHNICAL PARAMETERS
Span Length: 6000 feet maximum (T1)
Input Sensitivity: -36 dBm minimum
Jitter Tolerance: ±132 nanoseconds
Bit Error Rate: <10^-6 operational limit
EXAMPLES
regenerator status Show all regenerators
regenerator test REG-001 Test specific regenerator
regenerator alignment T1-SPAN-5 Align regenerator timing
SEE ALSO
t1carrier(1), multiplex(1), testboard(1)
BELL SYSTEM PRACTICES
BSP 362-150-001 - T1 Regenerator Maintenance