Skip to content

lmos


NAME
     lmos - Loop Maintenance Operations System

SYNOPSIS
     lmos [status]
     lmos line <telephone number>
     lmos reports | chronic | utilisation
     lmos treat [coin|force]

DESCRIPTION
     LMOS is a component of an Automated Repair Service Bureau. It
     mechanises the bureau's customer line card records by holding them in
     computer memory, and produces management reports from them. Its
     functions are customer trouble report processing, control of mechanised
     testing, analysis of past trouble reports through TREAT, and equipment
     utilisation reporting. One installation held up to five million
     customer line records.

     The bureau it belongs to has three stated objectives: improve efficiency
     and reduce the cost of repair operations, reduce the time required to
     detect, locate and repair troubles, and improve the handling of customer
     contacts by repair service attendants.

OPTIONS
     status            Line records held, reports in process, testing
     line <number>     One customer line card record and its trouble history
     reports           Trouble reports the bureau has in process
     chronic           Lines carrying three or more reports
     treat             Trouble report evaluation and analysis
     treat coin        Coin telephone operation
     treat force       Repair force administration
     utilisation       Equipment utilisation report

TESTING
     Three test systems worked with the bureau. The line status verifier and
     automated line verification equipment both had limited capability.
     Mechanised loop testing "provides mechanization of essentially all ARSB
     test functions", which is why mlt(1) is the command you will actually
     spend the shift in.

NOTES
     The chronic-line threshold of three reports is this simulation's own. No
     source available to it states the Bell System's own figure.

QUALIFICATION
     Requires the Main Distributing Frame sign-off.

     lmos cable      Group the pending board by cable and binder group.
                     Water is a sheath fault: several reports in one
                     twenty-five-pair binder group is what it looks like,
                     and one splicer trip repairs all of them.

SEE ALSO
     report(1), mlt(1), cosmos(1), qual(1)