sarts
Positions with this command: field (Field Support Liaison), sarts (SARTS (Switched Access Remote Test) Technician).
NAME
sarts - Switched Access Remote Test System
SYNOPSIS
sarts [status]
sarts list | trouble | access | categories
sarts circuit <circuit id>
sarts test <circuit id>
DESCRIPTION
Special services are everything that is not ordinary service. Ordinary
service is residence, public telephone, mobile and basic
individual-line business service; all the rest require special
treatment as to transmission, signalling, switching, billing or
customer use, and are used mostly by business customers. There were
about twenty-five major categories.
SARTS reaches those circuits without anybody driving anywhere. The
Switched Maintenance Access System, through the use of relays, provides
concentrated metallic access to individual circuits to permit that
remote access and testing. In the digital environment, digital access
and cross-connect test access serves the same purpose as jack or SMAS
arrangements.
A circuit on manual jack access cannot be reached from this position.
That is the whole point of the distinction, and the command will say so
rather than pretending otherwise.
OPTIONS
status Inventory, troubles, and what is reachable
list Every circuit on this position
trouble Circuits reported in trouble
circuit <id> One circuit's record
test <id> Reach a circuit and measure it
access The access arrangements and what each means
categories What counts as a special service
MEASUREMENT
A four-wire circuit is measured on a 105-type responder, which returns
two-way loss, noise, noise with tone and gain slope. A two-wire circuit
gets the 100-type far-end test line: one-way loss and noise. Both are
read at 1004 Hz.
A circuit that measures clean is returned to service. One outside its
working limits is held, because a special service out of limits should
not go back to the customer.
NOTES
Circuit identifiers here follow a plausible shape rather than the
COMMON LANGUAGE circuit identification format, which no document
available to this project sets out in full. Per-category circuit counts
and trouble rates are this simulation's own. Seven of the nine service
categories are attested by name in the period documents SOURCES.md
lists; 'sarts categories' marks which.
QUALIFICATION
Requires the Switching Control Center sign-off.
SEE ALSO
testline(1), testboard(1), testcall(1), trunk(1)
REPAIR
sarts repair <circuit id | row>
sarts repair <circuit id | row> office | facility | premises
The SARTS (Switched Access Remote Test) Technician desk only. For a
circuit held in trouble: the first form loops it back at this
office, at the far end of the facility and at the customer's end,
and prints what each read. Each loop reads everything between it
and this office, so the trouble is in the stretch after the last
loop that passed. The second form sends the force for that place.
A row is a row of the board 'sarts trouble' printed.
A force is not sent to a circuit nobody has read this tour: it
needs a 'sarts test' (SMAS and DACS access only) or a loop-back
first, and is refused, with no time spent, until it has one. The
right place clears the circuit. The wrong one finds nothing, costs
the trip and 12 minutes more to bring the force back and send it
again, and leaves the circuit out.
Every minute a circuit is held in trouble is counted against the
tour, by the shift clock and by nothing else, and sarts trouble
shows it. One held past 60 minutes counts as a missed commitment on
the index whether or not you look, and so does one cleared after
60; the first tour is a grace. Looping a circuit on SMAS or DACS
access is done by relay and costs 3 minutes; one on manual jack
access needs a visit and costs 15. The force costs 10 minutes at
the office, 20 on the facility and 15 at the customer's end. The
places, their odds, these minutes and the 60 are the simulation's
own. Engineering and Operations notes only, at p. 581 [598] n. 4,
that "in the case of special services, troubles may be traced to
interoffice facilities".