testcall
Positions with this command: sarts (SARTS (Switched Access Remote Test) Technician).
NAME
testcall - place a test call through the network
SYNOPSIS
testcall
testcall <from> <to>
testcall <from> <to> <test line>
DESCRIPTION
A test call is how a trunk is proved. The originating office seizes it,
outpulses the address, the network advances the call through the
hierarchy, and something at the far end answers so the connection can
be measured. Every stage leaves a signal a craftsperson can read.
STAGES
Seizure Single frequency signalling puts 2600 Hz on an idle
trunk. Seizing it removes the tone toward the far end,
which is what the far end is watching for.
Start signal The far end says when its register is ready. Wink
start winks off-hook and back; delay dial holds
off-hook until the register frees; immediate start
does neither and relies on a fixed interval.
Address Outpulsed in multifrequency, bracketed by KP to open
the register and ST to release it. The talking path is
muted while an office outpulses, which is why MF needs
no protection against the human voice and Touch-Tone
does.
Route advance Each group is offered in turn. A call goes to a
high-usage group first and overflows up its homing
chain to a final group. When every trunk in a final
group is busy the call is blocked and the caller gets
reorder.
Answer Answer supervision comes back and the tone is off in
both directions.
Release The tone is restored and the trunk returns to idle.
MEASUREMENT
Name a test line as the third argument and the call terminates on it,
so the connection itself is measured rather than merely completed. Loss
accumulates on every trunk in tandem, so a call that took five is
measurably worse than one that took three.
A circuit outside its working limits should not go back in service.
NOTES
Test numbers and test line access codes here are the simulation's own.
Real ones were carried in office records, office by office, not in any
national list. Which start arrangement a trunk group used was an office
record too; the choice here is deterministic on the office code so a
group answers the same way every time it is tested.
QUALIFICATION
Requires the Interoffice Trunks sign-off.
SEE ALSO
testline(1), testboard(1), routing(1), dialtone(1), trunk(1)