testline
Positions with this command: sarts (SARTS (Switched Access Remote Test) Technician).
NAME
testline - reach a test line or responder and read the result
SYNOPSIS
testline
testline <code>
testline <code> <circuit>
DESCRIPTION
Transmission testing is done against equipment at the far end of the
circuit that answers automatically. The Bell System Technical Journal
for April 1982 names the series:
102-type Far-end test line for a one-way loss measurement
100-type Far-end test line for one-way loss and noise
105-type Responder giving two-way loss, noise, noise with tone and
gain slope
Balance Connects the balance termination so office balance can be
measured
ROTL Remote office test line. Seizes a trunk from the far office
under command and connects it to a 52A responder
Every loss reading is taken at 1004 Hz, because that is the frequency
the Bell System stated its loss objectives at. A reading at any other
frequency is not measuring what the objective is written against.
CAROT
Centralized Automatic Reporting On Trunks drives the remote office test
line with multifrequency signalling and routines trunk groups without
anybody asking it to. Its exceptions print to the maintenance teletype.
The processor controlled interrogator works the same equipment from the
local office or a switching control centre when CAROT is not involved.
NOTES
The access codes shown are the simulation's own. Real test line access
codes were local to each office and carried in office records, not in
any national list.
SEE ALSO
testboard(1), trunk(1), mlt(1)