Skip to content

testboard


NAME
     testboard - central office test board

SYNOPSIS
     testboard
     testboard loop <report>
     testboard supervision <circuit>
     testboard results

DESCRIPTION
     The board is where the three testing systems meet. Loop measurement
     goes through mechanised loop testing, transmission goes through the
     test line series, and supervision is what single frequency signalling
     shows about a trunk.

OPTIONS
     loop <report>          Measure a subscriber loop. Same as mlt(1)
     supervision <circuit>  Single frequency supervision state of a trunk
     results                Every measurement taken this session
     status                 Board status and what is on it

SUPERVISION
     Single frequency signalling puts 2600 Hz on a trunk while it is idle
     and removes it when the trunk is seized. That makes the tone a
     supervisory signal a craftsperson reads directly:

     Tone on, trunk idle                normal
     Tone off, trunk seized             normal
     Tone on far end only               far end released, near end has not
     Tone present during a connection   irregularity. Report it and hold the
                                        circuit out of service

     Routine testing of these groups is run by CAROT, which reports its
     exceptions to the maintenance teletype whether anybody is reading or
     not.

SEE ALSO