toll
Positions with this command: switch (Switching Station Technician).
NAME
toll - the toll network
SYNOPSIS
toll
toll hierarchy
toll load
DESCRIPTION
The toll network consists of the class 4 and higher offices. Class 5 is
the end office, where subscriber loops terminate, and is not part of
it. This command shows the network as the routing engine holds it: how
many offices sit at each class, what homes on what, and how the trunk
groups between them are loaded.
Each office is joined to one of higher class by a final group and is
said to home on it. A call is completed at the lowest level of the
hierarchy that can carry it, using the fewest trunks in tandem, which
is why a typical toll connection takes three: up a toll connecting
trunk, across one intertoll group, and back down.
OPTIONS
(none) Offices by class, and trunking summary
hierarchy The homing chain, class by class
load Trunk group occupancy
GRADE OF SERVICE
Final trunk groups are engineered to P.01 - one call in a hundred finds
all trunks busy. High-usage groups are engineered to P.10, because
overflowing is what they are for.
QUALIFICATION
Requires the Toll Network sign-off.
SEE ALSO
routing(1), testcall(1), trunk(1), traffic(1), tnds(1)
QUALIFICATION VERB
toll control <block|reroute|off>
Held with the Toll Network sign-off. Puts a network management control
on, which holds calls off a route. Fewer calls that never complete
means fewer no-trouble reports reach the bureau: block cuts them to
four in ten of what they were, reroute to seven in ten. It also keeps
real customers off the network, and every report that arrives while
it is on carries a commitment shorter by 20 minutes for block and 8
for reroute. It stays on for the rest of the tour, until it is taken
off with toll control off. Engineering
and Operations notes that manual controls are often left in effect
too long. It costs 10 minutes to put on and 10 to take off.