mlt


NAME
     mlt - mechanised loop testing

SYNOPSIS
     mlt <report number | telephone number>

DESCRIPTION
     Measure a subscriber loop from the test desk and report the readings.
     Two different measurements are reported and they must not be confused.

     Insulation resistance is taken with the loop open and the office
     battery removed. It is high on a healthy pair - hundreds of thousands
     of ohms or more - and low wherever a fault is bridging something. Tip
     to ring, tip to ground and ring to ground are each read separately,
     because which one is low is what tells you what the fault is.

     Loop resistance is the resistance of the pair itself with the loop
     closed. It is the number the 1300-ohm design limit applies to, and an
     open pair has none to read.

     Capacitance is the third reading and the most useful one. Local
     exchange cable runs 0.083 microfarads to the mile, so a capacitance
     measurement on an open pair is a distance to the break.

READING THE RESULT
     Infinite tip to ring, no station termination      open
     Near zero tip to ring                             short
     One conductor low to ground, tip to ring normal   ground
     Foreign potential with no battery applied         foreign EMF
     Several pairs low in one cable                    wet cable
     Everything within limits, loop closed, current    receiver off hook
     Loop clean to the frame, customer still cut off   office equipment

DESIGN LIMITS
     Loops of 18 kft or less were designed to 1300 ohms maximum and
     nonloaded. Loops between 18 and 24 kft were designed to 1500 ohms with
     H88 loading. Anything longer went on digital loop carrier. A coin
     station needs 23 milliamperes to operate, which puts its own range
     limit at the same 1300 ohms, about three miles.

DIFFICULTY
     On the forgiving setting the system names the condition it reads for
     the first four times you meet each kind of trouble: the first two with
     the condition, the crew and a note on why the numbers say so, the next
     two with the crew alone. From the fifth it prints the numbers and
     nothing else, because reading them is the job. The count is kept for
     the whole career, for each kind of trouble separately, and a crew's
     report of what they cleared follows the same count. The other
     setting prints the numbers from the start. 'set assist.annotate on'
     keeps the notes for good; 'off' drops them at once.

NOTES
     The abbreviation table in Engineering and Operations expands MLT as
     "mechanical loop testing". The system was more widely called Mechanized
     Loop Testing. The conflict is recorded here rather than resolved.